Auditory Osseointegrated Implants
Clinical Determination and Indication Number: 00042
Original Effective Date: March 1, 2025
Last Review Date: March 1, 2025
I. Disclaimer
This document is intended to be used as a reference for non-VA providers and is not intended to replace clinical judgment when determining care pathways. These guidelines do not guarantee benefits or constitute medical advice.
II. Clinical Determinations and Indications
- Indications for Auditory Osseointegrated Implants
Auditory osseointegrated implants (bone anchored hearing aids, or
osseointegrated implants) are medically necessary prosthetics indicated for unilateral conductive, bilateral conductive, or mixed conductive sensorineural hearing loss for Veterans who have ANY of the following conditions which prevent use of a conventional air conduction hearing aid:- Congenital, traumatic, inflammatory, or post-surgical malformations of the external ear canal or middle ear
- Dermatitis of the ear canal
- Hearing loss secondary to ossicular disorders in persons who cannot undergo surgery
- Severe chronic otitis externa or otitis media
- Other conditions where an air conduction hearing aid is medically contraindicated
Note: This document does not pertain to non-surgical bone conduction hearing aids.
- Audiologic Criteria for Unilateral Auditory Osseointegrated Implants
- Unilateral use of a Food and Drug Administration (FDA) approved auditory osseointegrated implant will be considered medically necessary when ANY of the following criteria are met:
- Conductive or mixed hearing loss with pure tone average bone conduction threshold appropriate to the device used
- Unilateral sensorineural hearing loss (single-sided deafness, i.e., unilateral hearing loss that is non-functional or amplifiable)
- Hearing thresholds in the non-affected ear must be appropriate to the device used
- Audiologic Criteria for Bilateral Auditory Osseointegrated Implants
Bilateral use of an FDA-approved auditory osseointegrated implant will be considered medically necessary when ALL the following criteria are met:- Moderate-to-severe bilateral symmetric conductive or mixed hearing loss
- Pure tone average bone conduction threshold appropriate to the device used in both ears
- Limitations/Exclusions
In limited circumstances, auditory osseointegrated implants are appropriate for the following conditions outside the specific medical conditions above (typically related to otitis preventing air conducting hearing aid use):- Bilateral pure sensorineural hearing loss
- Bone conduction thresholds greater than 55 dB in both ears
For all indications not listed in section II.a. of this document, auditory osseointegrated implants are considered not medically necessary due to insufficient evidence of efficacy and safety.
- Description of Treatment
- Auditory osseointegrated implants consist of an external removable sound processor and an implant that is surgically anchored to the bone behind the ear (mastoid cortex). Depending on the system, the implant may penetrate the skin and directly connect to the sound processor or may be implanted under intact skin so that the external sound processor can be connected via a magnetic coupling to the implant. Sound vibrations are detected by a microphone on the sound processor, which sends a signal to the internal device and vibrates the bone of the skull. The sound is conducted through the bone of the skull directly to the inner ear (cochlea), a process known as direct bone conduction.
Surgical implantation of an auditory osseointegrated implant is typically an outpatient procedure performed by an otolaryngologist in the operating room and requires anesthesia care. The device can be used once the implant osseointegrates (fuses) with the bone which is usually about one to two months after implantation.
III. Background and Supporting Information
The following information is for reference purposes only in accordance with the medical benefits package outlined in 38 C.F.R. § 17.38 (b). Each subsection supports VA’s determinations for medical necessity and alignment with generally accepted standards of medical practice.
- Background Information
Hearing loss is a common worldwide health concern that becomes more prevalent and severe with age. Hearing loss is described as either conductive, sensorineural, or mixed. Conductive hearing loss occurs when sound is not conducted efficiently through the outer ear canal to the eardrum and the tiny bones (ossicles) of the middle ear. Sensorineural hearing loss occurs when there is damage to the inner ear (cochlea), or to the nerve pathways from the inner ear to the brain. Mixed hearing loss is when a person has a combination of both conductive hearing loss and sensorineural hearing loss. Any type of hearing loss can have a significant negative impact on a person’s quality of life (QOL) and ability to carry out daily living activities.
Auditory osseointegrated implants enhance natural bone conduction as a pathway for sound to travel to the inner ear. They are used to treat both conductive and mixed hearing loss. Auditory osseointegrated implants can produce clear sound perception if the cochlea is intact, regardless of the functionality of the outer and middle ear. These devices do not cure hearing loss or restore hearing ability completely; however, they can improve a person’s quality of hearing, which can positively impact their QOL.
- Research, Clinical Trials, and Evidence Summaries
There is substantial evidence in peer-reviewed medical literature supporting the use of bone anchored (osseointegrated) hearing devices for hearing impaired patients who do not benefit from the use of conventional hearing devices.
The 2021 American Academy of Otolaryngology-Head and Neck Surgery position statement, “considers bone conduction hearing devices (BCHD) as appropriate, and in some cases preferred, for the treatment of conductive and mixed hearing loss. Bone conductive hearing devices may also be indicated in select patients with single-sided deafness. These BCHD include semi implantable bone conduction devices utilizing either a percutaneous or transcutaneous attachment, as well as bone conduction oral appliances and scalp-worn devices”.
The April 2022 Journal of Otology and Neurotology issued a consensus statement that asserts BCHD are a proven, indispensable treatment option for hearing impaired patients who cannot use conventional, non-implantable hearing devices.
Hampton et al. (2022) conducted a systematic review and meta-analysis to evaluate the effect of bone conduction hearing devices on QOL in patients with single-sided sensorineural deafness (SSD). Inclusion criteria included studies with ten or more participants diagnosed with SSD, who had unilateral bone conduction hearing device implants and assessment of QOL before and after implantation. The main outcome measure was a mean change in QOL scores at six months after insertion of bone conduction hearing devices. The three QOL assessments used in the studies included the Abbreviated Profile of Hearing Aid Benefit (APHAB), the Health Utilities Index-3 (HUI3), and the Speech, Spatial and Qualities of Hearing Scale (SSQ). The APHAB and the SSQ are hearing-related QOL measures, while the HUI3 is a generic QOL measure. Eleven studies (203 participants) were used for this analysis. The results showed a significant statistical and clinically meaningful improvement in the APHAB scores and the SSQ hearing qualities, speech, and special hearing scores. There was no significant change in the mean HUI3 scores. The authors concluded that adult patients who receive BCHD may experience improvements in hearing specific QOL.
Cowan et al. (2024) conducted a study to evaluate clinical performance, safety, and patient reported outcomes of an active osseointegrated bone conduction hearing implant system. The study included 20 adult participants, 17 participants with mixed or conductive hearing loss and 3 participants with SSD deafness. Pre- and six-month post-implantation data was collected retrospectively. Follow up was completed 12 to 24 months post-implantation. Outcome measures included safety data, audiological thresholds, speech recognition thresholds in noise, and patient-reported outcomes. Results showed that there was no statistically significant change in free field hearing or speech reception thresholds in noise, indicating that aided improvements were maintained up to 24 months post-implantation. Improvements in health related QOL, daily hearing ability, and clinical and subjective measures of hearing benefit remained stable. There were no serious adverse events reported. Authors concluded the evidence supports the longer-term clinical safety, hearing performance, and patient-related benefits of the bone conduction hearing implant system.
- U.S. Food & Drug Administration Information
VA generally only approves use of medical devices that have received at least Food & Drug Administration (FDA) clearance for 510(k) Premarket Notification. The FDA has determined these Class II devices are substantially equivalent (SE) to legally marketed predicate devices and may be marketed in the U.S.
To search for devices that have received FDA 510(k) clearance or Premarket Approval (PMA), please visit the FDA Devices database.
- Medicare Coverage Determinations
Currently there are no available Medicare National Coverage Determinations (NCDs) or Local Coverage Determinations (LCDs) for auditory osseointegrated implants. VA and Medicare are governed by separate laws and regulations; thus, VA coverage determinations may be different.
- TRICARE Policy Manual
Available TRICARE coverage determinations are listed below as a resource. VA and TRICARE are governed by separate laws and regulations; thus, VA coverage determinations may be different.
TRICARE Policy Manual 6010.60-M, Chapter 07, Section 8.3
IV. Definitions
| Term | Definition |
|---|---|
| Abbreviated Profile of Hearing Aid Benefit (APHAB) | A 66-item self-assessment, disability-based inventory that can be used to document the outcome of a hearing aid fitting, to compare several fittings, or to evaluate the same fitting over time |
| Conductive Hearing Loss | When sounds cannot get through the outer and middle ear due to a blockage of the ear canal, a hole in the ear drum, problems with the small bones in the ear, or fluid in the space between the ear drum and cochlea |
| Health Utilities Index-3 (HUI3) | A group of health questionnaires designed to measure health status and reporting health-related quality of life |
| Mixed Hearing Loss | When conductive hearing loss happens at the same time as a sensorineural hearing loss, indicating possible damage in the outer or middle ear and in the inner ear or nerve pathway to the brain |
| Osseointegrated | Bone ingrowth into a metal implant; this ingrowth can be used for anchoring an external prosthesis directly to the bone |
| Otolaryngologists | Physicians who specialize in disorders related to the ear, nose, and throat |
| Pure Tone Audiogram | A hearing test that is the gold standard of determining the type, degree, and configuration of hearing loss |
| Pure Tone Average | The average calculated from the results of a pure tone audiogram of hearing sensitivity at 500, 1000, and 2000 dB |
| Sensorineural | Hearing loss due to a pathology of the cochlea, auditory nerve, or central nervous system |
| Speech, Spatial and Qualities of Hearing Scale (SSQ) | A questionnaire designed to assess a person’s ability and experience hearing and listening in different situations |
V. References
Centers for Medicare Services Medicare Benefit Policy Manual (2014, November 6).
General Exclusions from Coverage. Chapter 16, Section 100.
Hampton, T., Milinis, K., Whitehall, E., & Sharma, S. (2022). Association of Bone Conduction Devices for Single-Sided Sensorineural Deafness With Quality of Life: A Systematic Review and Meta-analysis. JAMA otolaryngology– head & neck surgery, 148(1), 35–42.
MCG Health. (2024, March 14). Hearing Aids, Bone Anchored and Bone Conduction. Ambulatory Care. 28th Edition.
Otology & Neurotology: official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology Consensus Statement on Bone Conduction Devices and Active Middle Ear Implants in Conductive and Mixed Hearing Loss. (2022)., 43(5), 513-529.
Quamina, S. D. (2024, March 6). Baha vs. Cochlear Implant: How to choose. Medical News Today.
U.S. Food & Drug Administration Medical Devices Database. (n.d.). Retrieved April 30, 2024.
VI. CDI History/Revision Information
- Explanation of changes to the CDI
| Revision Type | Date of Revision | Updates Made to CDI |
|---|---|---|
| N/A | MM/DD/YYYY | N/A |