Implantable Continuous Glucose Monitor (I-CGM)
Clinical Determination and Indication Number: 00049
Original Effective Date: July 1, 2025
Last Review Date: July 1, 2025
I. Disclaimer
This document is intended to be used as a reference for non-VA providers and is not intended to replace clinical judgment when determining care pathways. These guidelines do not guarantee benefits or constitute medical advice.
II. Clinical Determinations and Indications
- Indications
(Normal Indent 2) {INSERT TREATMENT NAME} is indicated for the treatment of {INSERT TOPIC} and will be considered medically necessary when ALL the following criteria are met:- Indications for Implantable Continuous Glucose Monitor
An implantable continuous glucose monitor (I-CGM) will be considered medically necessary when ONE of the following criteria is met:- Diagnosis of diabetes mellitus (any type) with a need to improve glycemic control, and requires daily insulin treatment to achieve desired glycemic control targets
- History of problematic hypoglycemia with documentation of at least one of the following:
- Recurrent (more than one) level 2 hypoglycemic event (glucose less than 54mg/dl) that persists despite multiple (more than one) attempts to adjust medication(s) and/or modify the diabetes treatment plan; or
- A history of one level 3 hypoglycemic event (glucose less than 54mg/dl) characterized by altered mental and/or physical state requiring third-party assistance for treatment of hypoglycemia
In addition to the above indications, documentation of intolerance to at least two conventional subcutaneous CGM devices is required to meet criteria for medical necessity.
- Indications for Continuation of an Implantable Continuous Glucose Monitor
Continuation of an I-CGM will be evaluated every six months following the initial prescription of the I-CGM. It will be considered medically necessary when the treating practitioner evaluates the patient and there is documentation of adherence to the I-CGM regimen and glycemic control treatment plan. In addition, there must be documentation that the device has resulted in clinical benefit (e.g., improved glycemic control, decrease in hypoglycemic events etc.).
- Indications for Implantable Continuous Glucose Monitor
- Limitations/Exclusions
An I-CGM is not indicated if any of the following are applicable:- Short-term (less than one week)
For all indications not listed in section II.a. of this document, I-CGM is considered not medically necessary due to insufficient evidence of efficacy and safety.
- Description of Treatment
An I-CGM is a prescription device for individuals with diabetes mellitus to continuously monitor and manage their glucose levels due to a higher risk for hypoglycemia based on their insulin regimen. During an outpatient procedure, a qualified healthcare provider implants a small sensor just under the skin. The sensor uses light-based technology to continuously measure glucose levels for up to 365 days. After 365 days, the sensor is removed and may be replaced if the patient continues to meet initial clinical criteria for I-CGM.The implanted sensor transmits data every five minutes to a compatible mobile device (e.g., smart phone or tablet). This real-time monitoring alerts users to potentially dangerous high (hyperglycemia) or low (hypoglycemia) glucose levels and potential adverse events
III. Background and Supporting Information
The following information is for reference purposes only in accordance with the medical benefits package outlined in 38 C.F.R. § 17.38 (b). Each subsection supports VA’s determinations for medical necessity and alignment with generally accepted standards of medical practice.
- Background Information
The Centers for Disease Control estimated that 38.4 million (11.6%) of the United States (U.S.) population had a diagnosis of diabetes mellitus in 2021. Diabetes mellitus is the eighth leading cause of death in the U.S. and studies show that deaths related to this chronic disease may be underreported. Diabetes mellitus as a comorbidity increases the risk of other serious health conditions including heart disease, stroke, blindness, kidney failure, and potential loss of limbs due to diabetic neuropathy and poor care.Accurate glucose monitoring is essential for managing patients with diabetes. There are numerous types of blood glucose monitors available, ranging from basic to more-advanced models with additional features. An implantable continuous glucose monitor (I-CGM) can assist with better management of glucose levels and decrease the likelihood of adverse events related to hypoglycemia and hyperglycemia. The I-CGM provides continuous wear for up to 365 days, unlike traditional continuous glucose monitoring that typically provides up to two weeks of monitoring. The transmitter can be removed and reattached easily without wasting supplies. Patients are not required to carry additional inserters, and the adhesive does not need to be replaced.
- Research, Clinical Trials, and Evidence Summaries
Implantable continuous glucose monitors provide real-time and long-term (up to 365 days) glucose monitoring options for patients with diabetes. Studies have demonstrated hemoglobin A1C (HbA1c) decreases in patients that use an I-CGM. Patients with diabetes may experience challenges when monitoring their glucose levels, including psychosocial challenges such as stigma or burnout. The I-CGM model provides support that can reduce this burden.Irace et al. (2020) conducted a prospective, multicenter, observational study among adult participants with type 1 diabetes across seven diabetes‐care centers. Individuals who had Eversense inserted for the first time were included. HbA1c was measured at baseline and at 180 days. Assessments of changes in time in range [TIR (glucose 70–180 mg/dL)], time above range [TAR (glucose >180 mg/dL)], time below range [TBR (glucose <70 mg/dL)] and glycemic variability were analyzed. Of the total participants, 56% were users of a continuous subcutaneous insulin infusion pump, and 45% had previously used a CGM system. Researchers evaluated data from participants’ previous use of CGM systems and the mode of insulin delivery used. A significant decrease in HbA1c was observed in patients after 180 days of wearing the Eversense I-CGM. A mean change in HbA1c of 0.35% (4 mmol/mol) from a baseline of 7.6% (60 mmol/mol) was detected. TIR significantly increased, TAR and mean daily sensor glucose significantly decreased, and TBR did not change after 180 days of sensor wear. The Eversense I-CGM demonstrated improved glycemic control outcomes in individuals with and without prior CGM experience. Authors concluded that the device shows promise as a diabetes management tool, assisting patients to achieve guideline‐directed targets for TIR.
Garg et al. (2022) performed a PROMISE study to evaluate the accuracy and safety of the next-generation Eversense I-CGM system for the duration of 180 days across the glucose ranges of 40–400 mg/dL. The prospective, multicenter, unblinded, nonrandomized study included individuals with type 1 and type 2 diabetes at eight sites in the U.S. Accuracy was evaluated by comparing the I-CGM to the Yellow Springs Instrument (YSI) 2300 glucose analyzer values during 10 clinic visits between day 1 and day 180. All participants (n=181) were inserted with one primary sensor. A second sensor, either an identical sensor or a modified sensor (sacrificial boronic acid [SBA]), was inserted into 96 subjects in the opposite arm. No serious adverse events related to the device or insertion/removal procedures were reported. Data showed the next-generation Eversense I-CGM had sustained accuracy and safety up to 180 days. I-CGM has an improved calibration scheme and survival, using the primary or SBA sensors. The accuracy of the I-CGM for detecting hypoglycemia and hyperglycemia events were similar or better than YSI 2300 glucose analyzer for a longer duration.
- U.S. Food & Drug Administration Information
VA generally only approves use of medical devices that have received at least FDA clearance for 510(k) Premarket Notification. The following device has received Premarket Approval from the FDA and is indicated for adults with diabetes mellitus (any type) for continuous measurement of glucose levels with diabetes for up to 180 days.To search for devices that have received FDA 510(k) clearance or Premarket Approval (PMA), please visit the FDA Devices database.
Information Description Product Name Eversense 365 Continuous Glucose Monitoring (CGM) System PMA Applicant Senseonics, Incorporated Address 20451 Seneca Meadows Parkway Germantown, Maryland 20876-7005 Approval Date September 16, 2024 Approval Letter K241335.pdf Information Description Product Name Eversense E3 Continuous Glucose Monitoring (CGM) System PMA Applicant Senseonics, Incorporated Address 20451 Seneca Meadows Parkway
Germantown, Maryland 20876-7005Approval Date March 29, 2023 Approval Letter P160048-S021.Letter.pdf
- Medicare Coverage Determinations
Available Medicare coverage determinations are listed below as a resource. VA and Medicare are governed by separate laws and regulations; thus, VA coverage determinations may be different.NCD Number Name Effective Date None N/A N/A LCD Number Name Original/Revision
Effective DateL38617 Novitas Solutions, Inc. 08/11/2024 L38657 Noridian Healthcare Solutions, LLC 02/25/2024 - NCD: National Coverage Determination
- LCD: Local Coverage Determination
- TRICARE Policy Manual
Available TRICARE coverage determinations are listed below as a resource. VA and TRICARE are governed by separate laws and regulations; thus, VA coverage determinations may be different.
- Health Care Procedural Coding Information
The following CPT®/HCPCS codes listed in this section are provided for informational purposes only. Inclusion or exclusion of a code does not constitute or imply VA coverage or provider reimbursement. The list of codes may not be all-inclusive since the American Medical Association (AMA) and Centers for Medicare & Medicaid Services (CMS) code updates may occur more frequently than CDI updates. Please refer to section II.a. in this document to review indications and clinical criteria for medical necessity.The following CPT codes are considered medically necessary/covered if the indications and clinical criteria outlined in section II.a. are met. Additional codes may also apply.
CPT Code Description 0446T Creation of subcutaneous pocket with insertion of implantable interstitial glucose sensor, including system activation and patient training 0447T Removal of implantable interstitial glucose sensor from subcutaneous pocket via incision 0448T Removal of implantable interstitial glucose sensor with creation of subcutaneous pocket at different anatomic site and insertion of new implantable sensor, including system activation CPT copyright 2024 American Medical Association. All rights reserved.
IV. Definitions
| Term | Definition |
|---|---|
| Glucose | The main type of sugar in the blood and the major source of energy for the body’s cells |
| Glycemic variability | Fluctuations in blood glucose levels |
| Hemoglobin A1C | A blood test that shows the average blood sugar (glucose) level over the past two to three months |
| Hyperglycemia | A condition that occurs when there is an excess of glucose (sugar) in the bloodstream; e.g., blood glucose level is greater than 125 mg/dL while fasting and greater than 180 mg/dL 2 hours postprandial (after meals) |
| Hypoglycemia | A condition that occurs when there is a depletion of glucose (sugar) in the bloodstream; e.g., blood glucose level is less than 70 mg/dL |
| Interstitial | The space between cells in a tissue |
| Sacrificial boronic acid [SBA] | Ingredient added to the implantable continuous glucose monitor (I-CGM) sensor that helps reduce the breakdown of the sensor components |
| Subcutaneous | Situated or applied under the skin |
V. References
Centers for Disease Control (2024, May 15). National Diabetes Statistics Report.
Medicare Coverage Database (n.d.). Local Coverage Determinations. Retrieved August 1, 2024.
VI. CDI History/Revision Information
| Date | Summary of Updates |
|---|---|
| 07/17/2025 | New CDI created describing medically necessary indications |