Cardiac Contractility Modulation
Clinical Determination and Indication Number: 00060
Original Effective Date: June 1, 2026
Last Review Date: June 1, 2026
I. Disclaimer
This document is intended to be used as a reference for non-VA providers and is not intended to replace clinical judgment when determining care pathways. These guidelines do not guarantee benefits or constitute medical advice.
II. Clinical Determinations and Indications
- Indications for Cardiac Contractility Modulation
The use of cardiac contractility modulation (CCM) for any conditions, including New York Heart Association Class III heart failure patients who remain symptomatic despite guideline directed medical therapy, is considered investigational and experimental. There is insufficient evidence from peer-reviewed medical literature to support the safety and efficacy of CCM for any conditions and is considered not medically necessary and not covered based on current evidence.
III. Background and Supporting Information
The following information is for reference purposes only in accordance with the medical benefits package outlined in 38 C.F.R. § 17.38 (b). Each subsection supports VA’s determinations for medical necessity and alignment with generally accepted standards of medical practice.
- Background Information
Heart failure, also known as congestive heart failure, is a serious condition when the heart does not pump enough blood to meet the body’s needs. According to the Centers for Disease Control and Prevention, heart failure affects about 6.2 million adults in the United States. Risk factors for heart failure include coronary artery disease, diabetes, high blood pressure, obesity, valvular heart disease, and other conditions related to heart disease. Lifestyle choices, including the use of alcohol and tobacco, poor diet, and low physical activity may increase the risk of heart failure. Heart failure may be acute or chronic and can affect one or both sides of the heart. Heart failure is commonly caused by damage to the heart by other medical conditions such as high blood pressure, heart inflammation, coronary artery disease or ischemic heart disease, cardiomyopathy, or arrhythmias. Diagnosis of heart failure is dependent on medical and family histories, physical exam findings, and results from imaging and blood tests. Currently, there is no cure for heart failure, but treatments such as lifestyle modifications, medications, medical devices, and procedures may improve the patients’ quality of life.Cardiac contractility modulation (CCM) therapy represents an emerging device-based treatment for heart failure patients who remain symptomatic despite optimal medical therapy. The therapy is delivered through a pacemaker-like device implanted under the skin of the upper chest with leads through the venous system into the right ventricle. The CCM device delivers non-excitatory electrical signals to the right ventricular septum during the absolute refractory period. The intended result of CCM is to improve patient’s 6-minute walk test distance, quality of life, functional status, and exercise tolerance. While initial studies have shown some promise in specific patient populations, the long-term clinical benefits and safety profile require further investigation through large-scale randomized controlled trials.
- Research, Clinical Trials, and Evidence Summaries
Cardiac contractility modulation therapy is an emerging adjunctive treatment for patients with moderate‑to‑severe heart failure with reduced ejection fraction (HFrEF) who remain symptomatic despite guideline-directed medical therapy (GDMT) and are not candidates for cardiac resynchronization therapy (CRT). The accumulated evidence demonstrates consistent improvements in symptoms, functional capacity, quality of life, and surrogate measures of cardiac remodeling, but data remains insufficient to firmly establish a mortality or hospitalization benefit, particularly in broader, more comorbid populations. Key limitations include modest sample sizes, variable blinding, device‑specific protocols, and under‑representation of women, older adults, and patients with complex multimorbidity. As a result, current professional society guidelines assign CCM a Class IIb recommendation (“may be considered”) in selected symptomatic HFrEF patients on GDMT who are not CRT candidates, reflecting potential benefit with persisting uncertainty.Suruagy-Motta et al. (2025) conducted a systematic review and single-arm meta-analysis of 15 observational studies, including 1,658 patients with symptomatic HFrEF who were ineligible for cardiac resynchronization therapy. The analysis evaluated the effects of CCM therapy on functional, structural, and quality of life outcomes. Cardiac contractility modulation therapy was associated with significant improvements in 6-minute walk test distance (mean increase: 44.96 meters), NYHA functional class (mean decrease: −0.89), and quality of life as measured by the Minnesota Living with Heart Failure Questionnaire (mean decrease: 11.83 points). Structural cardiac benefits included a mean increase in left ventricular ejection fraction (LVEF) of 5.96%, and reductions in left ventricular end-systolic and end-diastolic volumes. Hospitalization for heart failure was reduced by 63% in studies reporting this outcome, and the pooled mortality rate was 10%, consistent with expectations for advanced HFrEF populations. The authors conclude that CCM therapy provided meaningful improvements in functional capacity, symptom relief, quality of life, and cardiac remodeling for symptomatic HFrEF patients who are not cardiac resynchronization therapy candidates, supporting its role in addressing a significant therapeutic gap. However, the certainty of evidence is low to moderate due to the observational nature of included studies, with a need for further large-scale randomized trials to validate long-term outcomes and reduce heterogeneity. The study supports CCM therapy as an effective device-based therapy for this patient population.
Hong et al. (2024) conducted a systematic review of clinical trials evaluating the outcomes of CCM therapy in patients with atrial fibrillation and heart failure. The review included five trials, encompassing a total of 199 patients with atrial fibrillation treated with CCM. Study designs ranged from device programming interventions to comparative analyses of CCM delivery in patients with atrial fibrillation versus those in normal sinus rhythm. Across studies, CCM therapy was associated with significant improvements in ejection fraction, functional status, and quality of life, with no statistically significant differences in therapy delivery or outcomes between atrial fibrillation and normal sinus rhythm cohorts (e.g., FIX-HF-5C2 trial, p=0.70; CCMHFpEF, p=0.617). The authors concluded that CCM is an effective therapy for patients with both heart failure and atrial fibrillation, demonstrating comparable benefits regardless of rhythm status. Study results support CCM therapy as a beneficial treatment option for heart failure patients with atrial fibrillation.
The 2022 AHA/ACC/HFSA guideline (Heidenreich et al., 2022) is a comprehensive, evidence-based clinical practice guideline developed through the systematic review of randomized controlled trials, meta-analyses, and high-quality observational studies to inform the management of heart failure. The guidelines highlight the role of multiple device-based therapies, including CCM, for select patients with heart failure who remain symptomatic despite optimal GDMT. The recommendations are grounded in clinical trial data demonstrating that CCM may improve functional status, quality of life, and reduce heart failure-related hospitalizations in appropriately selected patients. Outcomes from referenced studies show that CCM therapy is associated with significant improvements in left ventricular ejection fraction and patient-reported outcomes, with a favorable safety profile. The guideline assigns a Class IIb recommendation for CCM, indicating that it may be considered in patients with symptomatic heart failure and reduced ejection fraction who are not candidates for cardiac resynchronization therapy and remain symptomatic despite GDMT. The authors conclude that CCM is a reasonable therapeutic option in this population.
Kuschyk et al. (2021) conducted a prospective, multicenter registry study (CCM-REG) involving 503 patients with moderate to severe heart failure across 51 European centers to evaluate the long-term clinical effects of CCM delivered by the Optimizer Smart System. The study assessed outcomes in subgroups stratified by left ventricular ejection fraction (LVEF ≤25%, 26–34%, ≥35%) and rhythm status (atrial fibrillation vs. normal sinus rhythm). Over a follow-up period of up to three years, CCM therapy was associated with significant improvements in functional status (mean NYHA class improvement of 0.6), quality of life (mean MLWHFQ improvement of 10 points), and LVEF (mean increase of 5.6%), all at 24 months (P < 0.001). Hospitalization rates for heart failure and cardiovascular events were markedly reduced compared to the year prior to CCM initiation (heart failure hospitalizations decreased from 0.74 to 0.25 events per patient-year, P < 0.0001). Survival at one and three years was significantly better than predicted by the validated Meta‐Analysis Global Group in Chronic Heart Failure Risk Score, particularly in patients with LVEF >25%. The authors conclude that CCM therapy may offer sustained improvements in symptom relief, quality of life, and reduced hospitalization rates, and recommend its use in patients with a LVEF ≤45% who remain symptomatic despite guideline-directed medical therapy.
- Medicare Coverage Determinations
Available Medicare national and local coverage determinations are listed below as a resource. VA and Medicare are governed by separate laws and regulations; thus, VA coverage determinations may be different.NCD Number Name Effective Date 20.39 Cardiac Contractility Modulation (CCM) for Heart Failure (HF) 10/28/2025 LCD Number Name Original/Revision
Effective DateNone N/A N/A - NCD: National Coverage Determination
- LCD: Local Coverage Determination
Note: CMS covers CCM for heart failure management under Coverage with Evidence Development (CED) when furnished in accordance with an U.S. Food & Drug Administration (FDA) market-authorized indication and the coverage criteria outlined in the NCD. For additional information about CCM’s coverage under CED, please reference the NCD.
- Health Care Procedural Coding Information
The following CPT®/HCPCS codes listed in this section are provided for informational purposes only. Inclusion or exclusion of a code does not constitute or imply VA coverage or provider reimbursement. The list of codes may not be all-inclusive since the American Medical Association (AMA) and Centers for Medicare & Medicaid Services (CMS) code updates may occur more frequently than CDI updates. Please refer to section II.a. in this document to review indications and clinical criteria for medical necessity.The following CPT codes are considered medically necessary/covered if the indications and clinical criteria outlined in section II.a. are met. Additional codes may also apply.
CPT Code Description 0408T Insertion or replacement of permanent cardiac contractility modulation system, including contractility evaluation when performed, and programming of sensing and therapeutic parameters; pulse generator with transvenous electrodes 0409T Insertion or replacement of permanent cardiac contractility modulation system, including contractility evaluation when performed, and programming of sensing and therapeutic parameters; pulse generator only 0410T Insertion or replacement of permanent cardiac contractility modulation system, including contractility evaluation when performed, and programming of sensing and therapeutic parameters; atrial electrode only 0411T Insertion or replacement of permanent cardiac contractility modulation system, including contractility evaluation when performed, and programming of sensing and therapeutic parameters; ventricular electrode only 0412T Removal of permanent cardiac contractility modulation system; pulse generator only 0413T Removal of permanent cardiac contractility modulation system; transvenous electrode (atrial or ventricular) 0414T Removal and replacement of permanent cardiac contractility modulation system pulse generator only 0415T Repositioning of previously implanted cardiac contractility modulation transvenous electrode, atrial or ventricular lead 0416T Relocation of skin pocket for implanted cardiac contractility modulation pulse generator 0417T Programming device evaluation (in person) with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with analysis, including review and report, implantable cardiac contractility modulation system 0418T Interrogation device evaluation (in person) with analysis, review and report, includes connection, recording and disconnection per patient encounter, implantable cardiac contractility modulation system 0915T Insertion of permanent cardiac contractility modulation-defibrillation system component(s), including fluoroscopic guidance, and evaluation and programming of sensing and therapeutic parameters; pulse generator and dual transvenous electrodes/leads (pacing and defibrillation) 0916T Insertion of permanent cardiac contractility modulation-defibrillation system component(s), including fluoroscopic guidance, and evaluation and programming of sensing and therapeutic parameters; pulse generator only 0917T Insertion of permanent cardiac contractility modulation-defibrillation system component(s), including fluoroscopic guidance, and evaluation and programming of sensing and therapeutic parameters; single transvenous lead (pacing or defibrillation) only 0918T Insertion of permanent cardiac contractility modulation-defibrillation system component(s), including fluoroscopic guidance, and evaluation and programming of sensing and therapeutic parameters; dual transvenous leads (pacing and defibrillation) only 0919T Removal of a permanent cardiac contractility modulation-defibrillation system component(s); pulse generator only 0920T Removal of a permanent cardiac contractility modulation-defibrillation system component(s); single transvenous pacing lead only 0921T Removal of a permanent cardiac contractility modulation-defibrillation system component(s); single transvenous defibrillation lead only 0922T Removal of a permanent cardiac contractility modulation-defibrillation system component(s); dual (pacing and defibrillation) transvenous leads only 0923T Removal and replacement of permanent cardiac contractility modulation-defibrillation pulse generator only 0924T Repositioning of previously implanted cardiac contractility modulation-defibrillation transvenous electrode(s)/lead(s), including fluoroscopic guidance and programming of sensing and therapeutic parameters 0925T Relocation of skin pocket for implanted cardiac contractility modulation-defibrillation pulse generator 0926T Programming device evaluation (in person) with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with analysis, including review and report, implantable cardiac contractility modulation-defibrillation system 0927T Interrogation device evaluation (in person) with analysis, review, and report, including connection, recording, and disconnection, per patient encounter, implantable cardiac contractility modulation-defibrillation system 0928T Interrogation device evaluation (remote), up to 90 days, cardiac contractility modulation-defibrillation system with interim analysis and report(s) by a physician or other qualified health care professional 0929T Interrogation device evaluation (remote), up to 90 days, cardiac contractility modulation-defibrillation system, remote data acquisition(s), receipt of transmissions, technician review, technical support, and distribution of results 0930T Electrophysiologic evaluation of cardiac contractility modulation-defibrillator leads, including defibrillation-threshold evaluation (induction of arrhythmia, evaluation of sensing and therapy for arrhythmia termination), at time of initial implantation or replacement with testing of cardiac contractility modulation-defibrillator pulse generator 0931T Electrophysiologic evaluation of cardiac contractility modulation-defibrillator leads, including defibrillation-threshold evaluation (induction of arrhythmia, evaluation of sensing and therapy for arrhythmia termination), separate from initial implantation or replacement with testing of cardiac contractility modulation-defibrillator pulse generator C1824 Generator, cardiac contractility modulation (implantable) CPT copyright 2026 American Medical Association. All rights reserved.
IV. Definitions
| Term | Definition |
|---|---|
| Absolute refractory period | The phase during which a cardiac muscle cell cannot respond to any stimulus, regardless of its strength. This ensures that the heart muscle has time to contract and relax before the next impulse |
| Atrial fibrillation | An irregular and often rapid heart rhythm (arrhythmia) that occurs when the upper chambers of the heart beat chaotically. This disrupts blood flow and increases the risk of stroke, heart failure, and other complications |
| Cardiac contractility modulation | An investigational and experimental therapy that delivers non-excitatory electrical signals to the heart during the absolute refractory period to enhance the strength of cardiac contractions in patients with heart failure who are not candidates for other device therapies |
| Cardiac remodeling | Changes in the size, shape, structure, and function of the heart after injury to the myocardium, such as a heart attack or chronic pressure overload. It is often associated with progression of heart failure |
| Cardiac resynchronization therapy | A treatment for heart failure that uses a specialized pacing device to coordinate the contractions of the heart’s ventricles, improving the heart’s efficiency and reducing symptoms |
| Chronic heart failure | A long-term condition where the heart cannot pump enough blood to meet the body’s needs. It may result from weakened or stiff heart muscle and can affect one or both sides of the heart with symptoms that include fatigue, shortness of breath, and fluid retention |
| Ejection fraction | The percentage of blood pumped out of the heart’s left ventricle with each contraction. A normal EF is 50–70%. Lower values may indicate heart failure or cardiomyopathy |
| Heart failure | An acute or chronic condition in which the heart cannot pump enough blood to meet the body’s needs. It may affect the right, left, or both sides of the heart |
| QRS complex | A segment of the heart’s electrical conduction system that reflects different aspects of ventricular depolarization. The QRS complex consists of a Q-, R- and S-wave, each providing key information about how the heart is functioning |
V. References
Suruagy‐Motta, R. F., Fukunaga, C. K., da Silva, E. V., Neves, G. R., Dos Santos, K. D., Vieira, L. L., … & de Carvalho, G. D. (2025). Cardiac Contractility Modulation In Symptomatic Heart Failure With Reduced Ejection Fraction: A Systematic Review and Single‐Arm Meta‐Analysis. Journal of Cardiovascular Electrophysiology.U.S. Food & Drug Administration Premarket Approval (PMA) Database. (n.d.). Retrieved February 12, 2025.
VI. CDI History/Revision Information
| Date | Summary of Updates |
|---|---|
| 06/01/2026 | New investigational/experimental CDI created |