Department of Veterans Affairs

Cardiac Contractility Modulation

Clinical Determination and Indication Number: 00060
Original Effective Date: June 1, 2026
Last Review Date: June 1, 2026

I. Disclaimer

This document is intended to be used as a reference for non-VA providers and is not intended to replace clinical judgment when determining care pathways. These guidelines do not guarantee benefits or constitute medical advice.

II. Clinical Determinations and Indications

  1. Indications for Cardiac Contractility Modulation
    The use of cardiac contractility modulation (CCM) for any conditions, including New York Heart Association Class III heart failure patients who remain symptomatic despite guideline directed medical therapy, is considered investigational and experimental. There is insufficient evidence from peer-reviewed medical literature to support the safety and efficacy of CCM for any conditions and is considered not medically necessary and not covered based on current evidence.

III. Background and Supporting Information

The following information is for reference purposes only in accordance with the medical benefits package outlined in 38 C.F.R. § 17.38 (b). Each subsection supports VA’s determinations for medical necessity and alignment with generally accepted standards of medical practice.

  1. Background Information
    Heart failure, also known as congestive heart failure, is a serious condition when the heart does not pump enough blood to meet the body’s needs. According to the Centers for Disease Control and Prevention, heart failure affects about 6.2 million adults in the United States. Risk factors for heart failure include coronary artery disease, diabetes, high blood pressure, obesity, valvular heart disease, and other conditions related to heart disease. Lifestyle choices, including the use of alcohol and tobacco, poor diet, and low physical activity may increase the risk of heart failure. Heart failure may be acute or chronic and can affect one or both sides of the heart. Heart failure is commonly caused by damage to the heart by other medical conditions such as high blood pressure, heart inflammation, coronary artery disease or ischemic heart disease, cardiomyopathy, or arrhythmias. Diagnosis of heart failure is dependent on medical and family histories, physical exam findings, and results from imaging and blood tests. Currently, there is no cure for heart failure, but treatments such as lifestyle modifications, medications, medical devices, and procedures may improve the patients’ quality of life.

    Cardiac contractility modulation (CCM) therapy represents an emerging device-based treatment for heart failure patients who remain symptomatic despite optimal medical therapy. The therapy is delivered through a pacemaker-like device implanted under the skin of the upper chest with leads through the venous system into the right ventricle. The CCM device delivers non-excitatory electrical signals to the right ventricular septum during the absolute refractory period. The intended result of CCM is to improve patient’s 6-minute walk test distance, quality of life, functional status, and exercise tolerance. While initial studies have shown some promise in specific patient populations, the long-term clinical benefits and safety profile require further investigation through large-scale randomized controlled trials.

  1. Research, Clinical Trials, and Evidence Summaries
    Cardiac contractility modulation therapy is an emerging adjunctive treatment for patients with moderate‑to‑severe heart failure with reduced ejection fraction (HFrEF) who remain symptomatic despite guideline-directed medical therapy (GDMT) and are not candidates for cardiac resynchronization therapy (CRT). The accumulated evidence demonstrates consistent improvements in symptoms, functional capacity, quality of life, and surrogate measures of cardiac remodeling, but data remains insufficient to firmly establish a mortality or hospitalization benefit, particularly in broader, more comorbid populations. Key limitations include modest sample sizes, variable blinding, device‑specific protocols, and under‑representation of women, older adults, and patients with complex multimorbidity. As a result, current professional society guidelines assign CCM a Class IIb recommendation (“may be considered”) in selected symptomatic HFrEF patients on GDMT who are not CRT candidates, reflecting potential benefit with persisting uncertainty.

    Suruagy-Motta et al. (2025) conducted a systematic review and single-arm meta-analysis of 15 observational studies, including 1,658 patients with symptomatic HFrEF who were ineligible for cardiac resynchronization therapy. The analysis evaluated the effects of CCM therapy on functional, structural, and quality of life outcomes. Cardiac contractility modulation therapy was associated with significant improvements in 6-minute walk test distance (mean increase: 44.96 meters), NYHA functional class (mean decrease: −0.89), and quality of life as measured by the Minnesota Living with Heart Failure Questionnaire (mean decrease: 11.83 points). Structural cardiac benefits included a mean increase in left ventricular ejection fraction (LVEF) of 5.96%, and reductions in left ventricular end-systolic and end-diastolic volumes. Hospitalization for heart failure was reduced by 63% in studies reporting this outcome, and the pooled mortality rate was 10%, consistent with expectations for advanced HFrEF populations. The authors conclude that CCM therapy provided meaningful improvements in functional capacity, symptom relief, quality of life, and cardiac remodeling for symptomatic HFrEF patients who are not cardiac resynchronization therapy candidates, supporting its role in addressing a significant therapeutic gap. However, the certainty of evidence is low to moderate due to the observational nature of included studies, with a need for further large-scale randomized trials to validate long-term outcomes and reduce heterogeneity. The study supports CCM therapy as an effective device-based therapy for this patient population.

    Hong et al. (2024) conducted a systematic review of clinical trials evaluating the outcomes of CCM therapy in patients with atrial fibrillation and heart failure. The review included five trials, encompassing a total of 199 patients with atrial fibrillation treated with CCM. Study designs ranged from device programming interventions to comparative analyses of CCM delivery in patients with atrial fibrillation versus those in normal sinus rhythm. Across studies, CCM therapy was associated with significant improvements in ejection fraction, functional status, and quality of life, with no statistically significant differences in therapy delivery or outcomes between atrial fibrillation and normal sinus rhythm cohorts (e.g., FIX-HF-5C2 trial, p=0.70; CCMHFpEF, p=0.617). The authors concluded that CCM is an effective therapy for patients with both heart failure and atrial fibrillation, demonstrating comparable benefits regardless of rhythm status. Study results support CCM therapy as a beneficial treatment option for heart failure patients with atrial fibrillation.

    The 2022 AHA/ACC/HFSA guideline (Heidenreich et al., 2022) is a comprehensive, evidence-based clinical practice guideline developed through the systematic review of randomized controlled trials, meta-analyses, and high-quality observational studies to inform the management of heart failure. The guidelines highlight the role of multiple device-based therapies, including CCM, for select patients with heart failure who remain symptomatic despite optimal GDMT. The recommendations are grounded in clinical trial data demonstrating that CCM may improve functional status, quality of life, and reduce heart failure-related hospitalizations in appropriately selected patients. Outcomes from referenced studies show that CCM therapy is associated with significant improvements in left ventricular ejection fraction and patient-reported outcomes, with a favorable safety profile. The guideline assigns a Class IIb recommendation for CCM, indicating that it may be considered in patients with symptomatic heart failure and reduced ejection fraction who are not candidates for cardiac resynchronization therapy and remain symptomatic despite GDMT. The authors conclude that CCM is a reasonable therapeutic option in this population.

    Kuschyk et al. (2021) conducted a prospective, multicenter registry study (CCM-REG) involving 503 patients with moderate to severe heart failure across 51 European centers to evaluate the long-term clinical effects of CCM delivered by the Optimizer Smart System. The study assessed outcomes in subgroups stratified by left ventricular ejection fraction (LVEF ≤25%, 26–34%, ≥35%) and rhythm status (atrial fibrillation vs. normal sinus rhythm). Over a follow-up period of up to three years, CCM therapy was associated with significant improvements in functional status (mean NYHA class improvement of 0.6), quality of life (mean MLWHFQ improvement of 10 points), and LVEF (mean increase of 5.6%), all at 24 months (P < 0.001). Hospitalization rates for heart failure and cardiovascular events were markedly reduced compared to the year prior to CCM initiation (heart failure hospitalizations decreased from 0.74 to 0.25 events per patient-year, P < 0.0001). Survival at one and three years was significantly better than predicted by the validated Meta‐Analysis Global Group in Chronic Heart Failure Risk Score, particularly in patients with LVEF >25%. The authors conclude that CCM therapy may offer sustained improvements in symptom relief, quality of life, and reduced hospitalization rates, and recommend its use in patients with a LVEF ≤45% who remain symptomatic despite guideline-directed medical therapy.

  1. Medicare Coverage Determinations
    Available Medicare national and local coverage determinations are listed below as a resource. VA and Medicare are governed by separate laws and regulations; thus, VA coverage determinations may be different.
    NCD NumberNameEffective Date
    20.39 Cardiac Contractility Modulation (CCM) for Heart Failure (HF)10/28/2025
    LCD NumberNameOriginal/Revision
    Effective Date
    None N/AN/A
    • NCD: National Coverage Determination
    • LCD: Local Coverage Determination

    Note: CMS covers CCM for heart failure management under Coverage with Evidence Development (CED) when furnished in accordance with an U.S. Food & Drug Administration (FDA) market-authorized indication and the coverage criteria outlined in the NCD. For additional information about CCM’s coverage under CED, please reference the NCD.

  1. Health Care Procedural Coding Information
    The following CPT®/HCPCS codes listed in this section are provided for informational purposes only. Inclusion or exclusion of a code does not constitute or imply VA coverage or provider reimbursement. The list of codes may not be all-inclusive since the American Medical Association (AMA) and Centers for Medicare & Medicaid Services (CMS) code updates may occur more frequently than CDI updates. Please refer to section II.a. in this document to review indications and clinical criteria for medical necessity.

    The following CPT codes are considered medically necessary/covered if the indications and clinical criteria outlined in section II.a. are met. Additional codes may also apply.

    CPT CodeDescription
    0408TInsertion or replacement of permanent cardiac contractility modulation system, including contractility evaluation when performed, and programming of sensing and therapeutic parameters; pulse generator with transvenous electrodes
    0409TInsertion or replacement of permanent cardiac contractility modulation system, including contractility evaluation when performed, and programming of sensing and therapeutic parameters; pulse generator only
    0410TInsertion or replacement of permanent cardiac contractility modulation system, including contractility evaluation when performed, and programming of sensing and therapeutic parameters; atrial electrode only
    0411TInsertion or replacement of permanent cardiac contractility modulation system, including contractility evaluation when performed, and programming of sensing and therapeutic parameters; ventricular electrode only
    0412TRemoval of permanent cardiac contractility modulation system; pulse generator only
    0413TRemoval of permanent cardiac contractility modulation system; transvenous electrode (atrial or ventricular)
    0414TRemoval and replacement of permanent cardiac contractility modulation system pulse generator only
    0415TRepositioning of previously implanted cardiac contractility modulation transvenous electrode, atrial or ventricular lead
    0416TRelocation of skin pocket for implanted cardiac contractility modulation pulse generator
    0417TProgramming device evaluation (in person) with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with analysis, including review and report, implantable cardiac contractility modulation system
    0418TInterrogation device evaluation (in person) with analysis, review and report, includes connection, recording and disconnection per patient encounter, implantable cardiac contractility modulation system
    0915TInsertion of permanent cardiac contractility modulation-defibrillation system component(s), including fluoroscopic guidance, and evaluation and programming of sensing and therapeutic parameters; pulse generator and dual transvenous electrodes/leads (pacing and defibrillation)
    0916TInsertion of permanent cardiac contractility modulation-defibrillation system component(s), including fluoroscopic guidance, and evaluation and programming of sensing and therapeutic parameters; pulse generator only
    0917TInsertion of permanent cardiac contractility modulation-defibrillation system component(s), including fluoroscopic guidance, and evaluation and programming of sensing and therapeutic parameters; single transvenous lead (pacing or defibrillation) only
    0918TInsertion of permanent cardiac contractility modulation-defibrillation system component(s), including fluoroscopic guidance, and evaluation and programming of sensing and therapeutic parameters; dual transvenous leads (pacing and defibrillation) only
    0919TRemoval of a permanent cardiac contractility modulation-defibrillation system component(s); pulse generator only
    0920TRemoval of a permanent cardiac contractility modulation-defibrillation system component(s); single transvenous pacing lead only
    0921TRemoval of a permanent cardiac contractility modulation-defibrillation system component(s); single transvenous defibrillation lead only
    0922TRemoval of a permanent cardiac contractility modulation-defibrillation system component(s); dual (pacing and defibrillation) transvenous leads only
    0923TRemoval and replacement of permanent cardiac contractility modulation-defibrillation pulse generator only
    0924TRepositioning of previously implanted cardiac contractility modulation-defibrillation transvenous electrode(s)/lead(s), including fluoroscopic guidance and programming of sensing and therapeutic parameters
    0925TRelocation of skin pocket for implanted cardiac contractility modulation-defibrillation pulse generator
    0926TProgramming device evaluation (in person) with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with analysis, including review and report, implantable cardiac contractility modulation-defibrillation system
    0927TInterrogation device evaluation (in person) with analysis, review, and report, including connection, recording, and disconnection, per patient encounter, implantable cardiac contractility modulation-defibrillation system
    0928TInterrogation device evaluation (remote), up to 90 days, cardiac contractility modulation-defibrillation system with interim analysis and report(s) by a physician or other qualified health care professional
    0929TInterrogation device evaluation (remote), up to 90 days, cardiac contractility modulation-defibrillation system, remote data acquisition(s), receipt of transmissions, technician review, technical support, and distribution of results
    0930TElectrophysiologic evaluation of cardiac contractility modulation-defibrillator leads, including defibrillation-threshold evaluation (induction of arrhythmia, evaluation of sensing and therapy for arrhythmia termination), at time of initial implantation or replacement with testing of cardiac contractility modulation-defibrillator pulse generator
    0931TElectrophysiologic evaluation of cardiac contractility modulation-defibrillator leads, including defibrillation-threshold evaluation (induction of arrhythmia, evaluation of sensing and therapy for arrhythmia termination), separate from initial implantation or replacement with testing of cardiac contractility modulation-defibrillator pulse generator
    C1824Generator, cardiac contractility modulation (implantable)

    CPT copyright 2026 American Medical Association. All rights reserved.

IV. Definitions

TermDefinition
Absolute refractory periodThe phase during which a cardiac muscle cell cannot respond to any stimulus, regardless of its strength. This ensures that the heart muscle has time to contract and relax before the next impulse
Atrial fibrillationAn irregular and often rapid heart rhythm (arrhythmia) that occurs when the upper chambers of the heart beat chaotically. This disrupts blood flow and increases the risk of stroke, heart failure, and other complications
Cardiac contractility modulationAn investigational and experimental therapy that delivers non-excitatory electrical signals to the heart during the absolute refractory period to enhance the strength of cardiac contractions in patients with heart failure who are not candidates for other device therapies
Cardiac remodelingChanges in the size, shape, structure, and function of the heart after injury to the myocardium, such as a heart attack or chronic pressure overload. It is often associated with progression of heart failure
Cardiac resynchronization therapyA treatment for heart failure that uses a specialized pacing device to coordinate the contractions of the heart’s ventricles, improving the heart’s efficiency and reducing symptoms
Chronic heart failureA long-term condition where the heart cannot pump enough blood to meet the body’s needs. It may result from weakened or stiff heart muscle and can affect one or both sides of the heart with symptoms that include fatigue, shortness of breath, and fluid retention
Ejection fractionThe percentage of blood pumped out of the heart’s left ventricle with each contraction. A normal EF is 50–70%. Lower values may indicate heart failure or cardiomyopathy
Heart failureAn acute or chronic condition in which the heart cannot pump enough blood to meet the body’s needs. It may affect the right, left, or both sides of the heart
QRS complexA segment of the heart’s electrical conduction system that reflects different aspects of ventricular depolarization. The QRS complex consists of a Q-, R- and S-wave, each providing key information about how the heart is functioning

V. References

Abraham, W. T., Kuck, K. H., Goldsmith, R. L., Lindenfeld, J., Reddy, V. Y., Carson, P. E., … & Hasenfuß, G. (2018). A randomized controlled trial to evaluate the safety and efficacy of cardiac contractility modulation. Heart Failure, 6(10), 874-883.

Abraham, W. T. (2021). Cardiac resynchronization therapy and cardiac contractility modulation in patients with advanced heart failure: How to select the right candidate?. Heart Failure Clinics, 17(4), 599-606.

Center for Disease Control and Prevention. (2023). Heart Failure. National Center for Chronic Disease Prevention and Health Promotion. Retrieved on October 16, 2025.

Heidenreich, P. A., Bozkurt, B., Aguilar, D., Allen, L. A., Byun, J. J., Colvin, M. M., … & Yancy, C. W. (2022). 2022 AHA/ACC/HFSA guideline for the management of heart failure: executive summary: a report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Journal of the American College of Cardiology, 79(17), 1757-1780.

Hong, J., Bilal, A., Sulemankhil, I., Khalife, W., & Sabayon, M. D. (2024). Outcomes Of Cardiac Contractility Modulation In Patients With Atrial Fibrillation: A Systematic Review Of Prior Trials. Journal of the American College of Cardiology, 83(13_Supplement), 244-244.

Kuschyk, J., Falk, P., Demming, T., Marx, O., Morley, D., Rao, I., & Burkhoff, D. (2021). Long‐term clinical experience with cardiac contractility modulation therapy delivered by the Optimizer Smart system. European journal of heart failure, 23(7), 1160-1169.

Masarone, D., Rao, I., & Pacileo, G. (2023). HOPE for a better selection of patients for cardiac contractility modulation. Expert Review of Medical Devices, 20(7), 525-528.

Masarone, D., Kittleson, M. M., D’Onofrio, A., Falco, L., Fumarulo, I., Massetti, M., … & Pacileo, G. (2024). Basic science of cardiac contractility modulation therapy: Molecular and electrophysiological mechanisms. Heart Rhythm, 21(1), 82-88.

McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., … & Kathrine Skibelund, A. (2021). 2021 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure: Developed by the Task Force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC) With the special contribution of the Heart Failure Association (HFA) of the ESC. European heart journal, 42(36), 3599-3726.

Salehin, S., Harmouch, W., Yaqub, M., Khan, U., Merie, A., Salehin, S., Hasan, S., Khalife, W., Sabayon, M., Chatila, K., Raja, M. (2024). Cardiac Contractility Modulation in Patients with Advanced Heart Failure: A Comprehensive Review of Literature,Current Problems in Cardiology,Volume 49, Issue 1, Part C, 2024, 102102, ISSN 0146-2806.

Suruagy‐Motta, R. F., Fukunaga, C. K., da Silva, E. V., Neves, G. R., Dos Santos, K. D., Vieira, L. L., … & de Carvalho, G. D. (2025). Cardiac Contractility Modulation In Symptomatic Heart Failure With Reduced Ejection Fraction: A Systematic Review and Single‐Arm Meta‐Analysis. Journal of Cardiovascular Electrophysiology.U.S. Food & Drug Administration Premarket Approval (PMA) Database. (n.d.). Retrieved February 12, 2025.

VI. CDI History/Revision Information

DateSummary of Updates
06/01/2026New investigational/experimental CDI created

We’re here anytime, day or night – 24/7