Department of Veterans Affairs

Cone Beam Computed Tomography 

Dental Clinical Determination and Indication Number: DNT-0015
Original Effective Date: November 1, 2026
Last Review Date: November 1, 2026

I. Disclaimer

This document is intended to be used as a reference for VA and non-VA providers. It is not intended to replace clinical judgment when determining care pathways. These guidelines do not guarantee benefits or constitute medical advice. 

Eligibility for VA dental care is defined by statute and is to be provided in accordance with the provisions of existing law and VA regulations, specifically 38 U.S.C. §§1710(c) and 1712, and 38 CFR §§17.160 through 17.166. 

II. Dental Clinical Determinations and Indications

  1. Indications for Cone Beam Computed Tomography   
    Cone Beam Computed Tomography (CBCT) may be considered clinically necessary for the treatment of complex dental conditions where three-dimensional imaging provides significant diagnostic benefits over two-dimensional imaging techniques when ANY of the following criteria are met: 
    • Preoperative assessment for dental implants, particularly when cross-sectional information is critical for evaluating bone volume, location of anatomic structures, and surgical planning  
    • Endodontic evaluation when clinical signs and symptoms and other diagnostic imaging are inconclusive 
    • Visualization of the maxillofacial skeleton to assess trauma, fractures, or anomalies where traditional radiographs fail to provide sufficient information 
    • Assessment of pathologies such as cysts, tumors, or lesions requiring precise localization and evaluation for treatment planning 

Note: When a CBCT is used, the provider should limit the radiation dose by optimizing image quality using the smallest field of view necessary at the lowest dose and scan time to obtain a diagnostic image of the area of interest. 

  1. Limitations/Exclusions
    Cone Beam Computed Tomography is not indicated and therefore considered not clinically necessary in the following situations: 
    • Routine dental diagnosis or screening purposes when two-dimensional imaging suffices 
    • When alternative lower-dose imaging can provide adequate information, given the higher radiation dose of CBCT compared to conventional radiography 

    For all other conditions or indications not listed in section II.a. of this document, use of CBCT is considered not clinically necessary due to insufficient evidence of efficacy and safety. 

  2. Description of Treatment
  3. When a CBCT scan is performed, a cone-shaped X-ray beam rotates around the patient’s head, capturing multiple images from different angles. These images are then compiled to generate volumetric data, which allows for the three-dimensional reconstruction of dental, jaw, and face structures. During the scan, the patient may be seated, standing, or lying down, depending on the specific equipment in use. The resulting high-resolution images provide detailed anatomical information that is critical for accurate diagnosis and effective treatment planning, particularly in complex cases. This advanced imaging technique offers more precise and comprehensive views of the structures compared to traditional two-dimensional radiography.  

III. Background and Supporting Information

The following information is for reference purposes only in accordance with dental eligibility as defined by statute (law). Each subsection supports VA’s determinations for clinical necessity and alignment with generally accepted standards of dental practice. 

  1. Background Information
    Cone Beam Computed Tomography (CBCT) emerged in the early 2000s as an alternative to medical-grade computed tomography for dental applications, providing enhanced spatial resolution with lower radiation exposure. Its adoption in dentistry has expanded due to its ability to visualize complex anatomy more effectively than conventional imaging. The diagnostic is particularly valuable in dental implantology, endodontics, and maxillofacial assessments.  
  1. Research, Clinical Trials, and Evidence Summaries
    Cone Beam Computed Tomography is a proven, safe, and effective imaging technique widely used for complex dental conditions requiring three-dimensional imaging. The high-resolution images provided by CBCT offer detailed anatomical information essential for accurate diagnosis and effective treatment planning. Tyndall et al. (2012) in Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology provide a position statement from the American Academy of Oral and Maxillofacial Radiology (AAOMR), emphasizing CBCT’s critical role in dental implantology for assessing bone volume and anatomical landmarks, aligning with its indication for surgical planning. The American Dental Association’s (ADA) advisory statement (2012) in The Journal of the American Dental Association reinforces CBCT’s diagnostic superiority over two-dimensional imaging for complex cases, while advocating for radiation safety via as low as reasonably achievable (ALARA) principles, supporting the document’s limitations on routine use. The American Association of Endodontists (AAE) and AAOMR joint statement (2015) in the same journal highlights CBCT’s ability to detect periapical pathosis in endodontic cases not visible on conventional radiographs, justifying its use in complex endodontic evaluations. The American College of Prosthodontists’ (2019) position statement further corroborates CBCT’s utility in implant treatment planning, emphasizing precise anatomical visualization. In summary, these authoritative positions collectively underscore the integral role of CBCT in enhancing diagnostic accuracy, treatment planning, and clinical outcomes across various dental specialties, while also advocating for the judicious use of this advanced imaging modality in alignment with radiation safety principles. 
  1. U.S. Food & Drug Administration Information
  2. VA generally only approves use of medical devices that have received at least Food & Drug Administration (FDA) clearance for 510(k) Premarket Notification. The FDA has determined these Class II devices are substantially equivalent (SE) to legally marketed predicate devices, in terms of safety and effectiveness, and may be marketed in the U.S. Manufacturers must adhere to FDA regulations on labeling, manufacturing practices, and post-market surveillance. The FDA monitors adverse event reports and can mandate recalls. Manufacturer’s Instructions for Use (MIFU) must be followed. 

    Cone Beam Computed Tomography devices are regulated by the FDA as Class II medical devices. The FDA provides guidance on their safe use, emphasizing minimizing radiation exposure by adhering to ALARA principles. Materials must comply with FDA standards for biocompatibility, durability, and safety under functional loads.  

    To search for devices that have received FDA 510(k) clearance or Premarket Approval (PMA), please visit the FDA Devices database.

  1. American Dental Association Current Dental Terminology Coding Information
  2. The following CDT codes listed in this section are provided for informational purposes only. Inclusion or exclusion of a code does not constitute or imply VA coverage or provider reimbursement. The list of codes may not be all-inclusive since the American Dental Association (ADA) code updates may occur more frequently than dental CDI updates. Please refer to section II.a. in this document to review indications and clinical criteria for clinical necessity. 
  3. CDT CodeDescription
    D0364  Cone beam CT capture and interpretation with limited field of view – less than one whole jaw  
    D0365  Cone beam CT capture and interpretation with field of view of one full dental arch – mandible  
    D0366  Cone beam CT capture and interpretation with field of view of one full dental arch – maxilla, with or without cranium  
    D0367  Cone beam CT capture and interpretation with field of view of both jaws; with or without cranium  
    D0368  Cone beam CT capture and interpretation for TMJ series including two or more exposures  
    D0380  Cone beam CT image capture with limited field of view – less than one whole jaw  
    D0381  Cone beam CT image capture with field of view of one full dental arch – mandible  
    D0382  Cone beam CT image capture with field of view of one full dental arch – maxilla, with or without cranium  
    D0383  Cone beam CT image capture with field of view of both jaws; with or without cranium  
    D0384  Cone beam CT image capture for TMJ series including two or more exposures  
    D0391  Interpretation of diagnostic image by a practitioner not associated with capture of the image, including report  
    D0393 Virtual treatment simulation using 3D image volume or surface scan; Virtual simulation of treatment including, but not limited to, dental implant placement, prosthetic reconstruction, orthognathic surgery and orthodontic tooth movement 
    D0394 Digital subtraction of two or more images or image volumes of the same modality; To demonstrate changes that have occurred over time 
    D0395 Fusion of two or more 3D image volumes of one or more modalities 
    D5985 Radiation cone locator; Synonymous terminology: docking device, cone locator. A prosthesis utilized to direct and reduplicate the path of radiation to an oral tumor during a split course of irradiation 

    Current Dental Terminology (CDT), Copyright © 2026 American Dental Association. All rights reserved.

IV. Definitions

TermDefinition
As low as reasonably achievable principle   A radiation safety principle for minimizing radiation doses and releasing as low as reasonably achievable 
Cone beam computed tomography A form of computed tomography where X-rays are divergent, forming a cone to provide three-dimensional imaging of the dental and maxillofacial region  
Field of view The extent of anatomy included in the cone beam computed tomography scan, which can range from small, localized areas to the entire maxillofacial region  

V. References

American College of Prosthodontists. (2019, February 24). Position Statement: Diagnostic Imaging in the Treatment Planning, Surgical, and Prosthodontic Aspects of Implant Dentistry. 

American Dental Association. (2026). CDT 2026: Current Dental Terminology. American Dental Association 

American Dental Association Council on Scientific Affairs (2012). The use of cone-beam computed tomography in dentistry: an advisory statement from the American Dental Association Council on Scientific Affairs. Journal of the American Dental Association (1939), 143(8), 899–902.   

Benavides, E., Krecioch, J. R., Allareddy, T., Buchanan, A., Keels, M. A., Mascarenhas, A. K., Duong, M. L., O’Brien, K. K., Ziegler, K. M., Lipman, R. D., Connolly, R. T., Cevidanes, L., Cordell, K., Elangovan, S., Fouad, A. F., González-Cabezas, C., Huja, S. S., Kademani, D., Khan, A., Malik, A., … Yepes, J. (2026). American Dental Association and American Academy of Oral and Maxillofacial Radiology patient selection for dental radiography and cone-beam computed tomography: Clinical recommendations. Oral surgery, oral medicine, oral pathology and oral radiology, 141(3), 273–287. 

Benavides, E., Krecioch, J. R., Connolly, R. T., Allareddy, T., Buchanan, A., Spelic, D., O’Brien, K. K., Keels, M. A., Mascarenhas, A. K., Duong, M. L., Aerne-Bowe, M. J., Ziegler, K. M., & Lipman, R. D. (2024). Optimizing radiation safety in dentistry: Clinical recommendations and regulatory considerations. Journal of the American Dental Association (1939), 155(4), 280–293.e4. 

Special Committee to Revise the Joint AAE/AAOMR Position Statement on use of CBCT in Endodontics (2015). AAE and AAOMR Joint Position Statement: Use of Cone Beam Computed Tomography in Endodontics 2015 Update. Oral surgery, oral medicine, oral pathology and oral radiology, 120(4), 508–512.     

Tyndall, D. A., Price, J. B., Tetradis, S., Ganz, S. D., Hildebolt, C., Scarfe, W. C., & American Academy of Oral and Maxillofacial Radiology (2012). Position statement of the American Academy of Oral and Maxillofacial Radiology on selection criteria for the use of radiology in dental implantology with emphasis on cone beam computed tomography. Oral surgery, oral medicine, oral pathology and oral radiology, 113(6), 817–826.  

UnitedHealthcare. (2024). UnitedHealthcare Dental Clinical Policy: Cone beam computed tomography. United healthcare  

U.S. Food and Drug Administration. (n.d.). Dental Cone-beam Computed Tomography. Retrieved October 10, 2025.  

VI. Dental CDI History/Revision Information

DateSummary of Updates
11/01/2026New dental CDI created describing clinically necessary indications / not clinically necessary indications 

We’re here anytime, day or night – 24/7

If you are a Veteran in crisis or concerned about one, connect with our caring, qualified responders for confidential help. Many of them are Veterans themselves.